{"product_id":"40w-480v-emergency-led-driver-battery-backup-ul-924","title":"40W 480V Emergency LED Driver | 277–480VAC Battery Backup | 90-Minute Runtime | Self-Testing | IP65 | UL 924 Listed | LSA-40AAAWW-HY","description":"\u003cstyle\u003e\n  details summary .acc-plus,\n  details[open] summary .acc-minus { display: inline; }\n  details summary .acc-minus,\n  details[open] summary .acc-plus { display: none; }\n\u003c\/style\u003e\n\n\u003cp style=\"font-size: 15px; line-height: 1.8; color: #444; margin-bottom: 10px;\"\u003e\n  This 40W emergency LED driver is purpose-built for 480V electrical systems, accepting a 277–480VAC input and delivering 310–500VDC emergency output to maintain illumination for a minimum of 90 minutes during a power failure. Designed exclusively for LED luminaires with 347–480VAC input voltage, the driver powers 0-10V dimmable fixtures up to 300W and fits inside high bays, troffers, and panel fixtures across industrial and commercial environments. Integrated self-diagnostic circuitry performs monthly 30-second and annual 90-minute discharge tests per NFPA 101, while the IP65-rated slim-profile body with flexible conduit wiring installs cleanly inside fixture housings. UL 924 Listed for the US and Canada and CEC Title 20 compliant, the unit includes a test switch and charge indicator kit and is backed by a 5-year warranty.\n\u003c\/p\u003e\n\n\u003cdetails style=\"border-top: 1px solid #ddd; margin-top: 16px;\"\u003e\n  \u003csummary style=\"cursor: pointer; padding: 14px 0; font-size: 17px; font-weight: 600; color: #222; list-style: none; display: flex; justify-content: space-between; align-items: center;\"\u003e\n    Key Features\n    \u003cspan\u003e\u003cspan class=\"acc-plus\" style=\"font-size: 22px; font-weight: 300; color: #c0392b;\"\u003e+\u003c\/span\u003e\u003cspan class=\"acc-minus\" style=\"font-size: 22px; font-weight: 300; color: #c0392b;\"\u003e−\u003c\/span\u003e\u003c\/span\u003e\n  \u003c\/summary\u003e\n  \u003cdiv style=\"display: flex; justify-content: space-around; text-align: center; padding: 20px 0 28px; flex-wrap: wrap; gap: 20px;\"\u003e\n\n    \u003cdiv style=\"flex: 1; min-width: 80px; max-width: 110px;\"\u003e\n      \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"48\" height=\"48\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#333\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\n        \u003cpolygon points=\"13 2 3 14 12 14 11 22 21 10 12 10 13 2\"\u003e\u003c\/polygon\u003e\n      \u003c\/svg\u003e\n      \u003cp style=\"font-size: 12px; margin-top: 8px; color: #444;\"\u003e40W\u003cbr\u003eEmergency Output\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex: 1; min-width: 80px; max-width: 110px;\"\u003e\n      \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"48\" height=\"48\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#333\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\n        \u003cpath d=\"M18 6l-2 4h3l-2 4\"\u003e\u003c\/path\u003e\n        \u003cpath d=\"M6 6l-2 4h3l-2 4\"\u003e\u003c\/path\u003e\n        \u003cline x1=\"21\" y1=\"3\" x2=\"21\" y2=\"21\"\u003e\u003c\/line\u003e\n        \u003cline x1=\"3\" y1=\"3\" x2=\"3\" y2=\"21\"\u003e\u003c\/line\u003e\n      \u003c\/svg\u003e\n      \u003cp style=\"font-size: 12px; margin-top: 8px; color: #444;\"\u003e277–480 VAC\u003cbr\u003eInput Range\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex: 1; min-width: 80px; max-width: 110px;\"\u003e\n      \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"48\" height=\"48\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#333\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\n        \u003ccircle cx=\"12\" cy=\"12\" r=\"10\"\u003e\u003c\/circle\u003e\n        \u003cpolyline points=\"12 6 12 12 16 14\"\u003e\u003c\/polyline\u003e\n      \u003c\/svg\u003e\n      \u003cp style=\"font-size: 12px; margin-top: 8px; color: #444;\"\u003e90-Minute\u003cbr\u003eEmergency Runtime\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex: 1; min-width: 80px; max-width: 110px;\"\u003e\n      \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"48\" height=\"48\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#333\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\n        \u003cpath d=\"M9 11l3 3L22 4\"\u003e\u003c\/path\u003e\n        \u003cpath d=\"M21 12v7a2 2 0 0 1-2 2H5a2 2 0 0 1-2-2V5a2 2 0 0 1 2-2h11\"\u003e\u003c\/path\u003e\n      \u003c\/svg\u003e\n      \u003cp style=\"font-size: 12px; margin-top: 8px; color: #444;\"\u003eSelf-Testing\u003cbr\u003eNFPA 101\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex: 1; min-width: 80px; max-width: 110px;\"\u003e\n      \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"48\" height=\"48\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#333\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\n        \u003cpath d=\"M12 22s8-4 8-10V5l-8-3-8 3v7c0 6 8 10 8 10z\"\u003e\u003c\/path\u003e\n        \u003cpolyline points=\"9 12 11 14 15 10\"\u003e\u003c\/polyline\u003e\n      \u003c\/svg\u003e\n      \u003cp style=\"font-size: 12px; margin-top: 8px; color: #444;\"\u003eUL 924\u003cbr\u003eListed\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex: 1; min-width: 80px; max-width: 110px;\"\u003e\n      \u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"48\" height=\"48\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#333\" stroke-width=\"1.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\n        \u003cpath d=\"M12 2a7 7 0 0 0-7 7c0 2 .5 3.5 2 5.5L12 22l5-7.5c1.5-2 2-3.5 2-5.5a7 7 0 0 0-7-7z\"\u003e\u003c\/path\u003e\n        \u003ccircle cx=\"12\" cy=\"9\" r=\"2.5\"\u003e\u003c\/circle\u003e\n      \u003c\/svg\u003e\n      \u003cp style=\"font-size: 12px; margin-top: 8px; color: #444;\"\u003eIP65\u003cbr\u003eWaterproof\u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border-top: 1px solid #ddd; margin-top: 16px;\"\u003e\n  \u003csummary style=\"cursor: pointer; padding: 14px 0; font-size: 17px; font-weight: 600; color: #222; list-style: none; display: flex; justify-content: space-between; align-items: center;\"\u003e\n    Specifications\n    \u003cspan\u003e\u003cspan class=\"acc-plus\" style=\"font-size: 22px; font-weight: 300; color: #c0392b;\"\u003e+\u003c\/span\u003e\u003cspan class=\"acc-minus\" style=\"font-size: 22px; font-weight: 300; color: #c0392b;\"\u003e−\u003c\/span\u003e\u003c\/span\u003e\n  \u003c\/summary\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; font-family: Arial, sans-serif; margin-bottom: 16px;\"\u003e\n\n    \u003ctr\u003e\n      \u003cth colspan=\"2\" style=\"background-color: #c0392b; color: #fff; padding: 9px 12px; text-align: left; font-size: 12px; letter-spacing: 0.8px; text-transform: uppercase;\"\u003eGeneral\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eEmergency LED Driver with Battery Backup (480V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eEmergency Output Wattage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e40W (Constant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eEmergency Runtime\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e90 Minutes (Minimum)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eRecharge Time\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e24 Hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eSelf-Testing\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eAutomatic — Monthly 30-Second \u0026amp; Annual 90-Minute (NFPA 101)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eFixture Compatibility\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eLED Luminaires with 347–480VAC Input Only\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eInstallation\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eField or Factory\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eWarranty\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e5 Years\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003cth colspan=\"2\" style=\"background-color: #c0392b; color: #fff; padding: 9px 12px; text-align: left; font-size: 12px; letter-spacing: 0.8px; text-transform: uppercase;\"\u003eElectrical\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e277–480 VAC, 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eInput Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e200mA Max\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eRecharge Power\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e12W Max\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eOutput Voltage (Emergency)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e310–500 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eMax Fixture Wattage (0-10V Dimming)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eUp to 300W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eOutput Design\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eConstant Power\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eDimming Compatibility\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e0-10V (Dimming Driver Required)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eSurge Protection\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e3kV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eBattery Protection\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eOver-Temperature, Over-Charge, Over-Discharge\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eBattery Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eLithium-Ion\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003cth colspan=\"2\" style=\"background-color: #c0392b; color: #fff; padding: 9px 12px; text-align: left; font-size: 12px; letter-spacing: 0.8px; text-transform: uppercase;\"\u003ePhysical\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eDimensions (Driver Body)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e12.33\" × 2.33\" × 1.66\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eConduit Length\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e13\" (Output Wire Exposed: 3.94\")\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eConnector Thread\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e½\"-14 NPSM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eIngress Protection\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eIP65\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e32°F – 122°F (0°C – 50°C)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eMaximum Mounting Height\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003e30.3 ft\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eWiring\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eFlexible Conduit (External Wires)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eForm Factor\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eSlim Profile for In-Fixture Mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eLocation Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eDamp Locations \u0026amp; Plenum Spaces (Indoor Only)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eTest Switch \/ Indicator\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eIncluded Kit (Metal or Plastic Indicator Options)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003cth colspan=\"2\" style=\"background-color: #c0392b; color: #fff; padding: 9px 12px; text-align: left; font-size: 12px; letter-spacing: 0.8px; text-transform: uppercase;\"\u003eCertifications\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eSafety Listing\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eUL Listed (US \u0026amp; Canada)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eStandards\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eUL 924 \/ CSA C22.2 No. 141\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eEnergy Compliance\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eCEC Title 20 (California)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; font-weight: 600; color: #222;\"\u003eCode Compliance\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 9px 12px; color: #444;\"\u003eNEC, IBC, NFPA 101 Life Safety Code\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border-top: 1px solid #ddd; margin-top: 16px;\"\u003e\n  \u003csummary style=\"cursor: pointer; padding: 14px 0; font-size: 17px; font-weight: 600; color: #222; list-style: none; display: flex; justify-content: space-between; align-items: center;\"\u003e\n    Features\n    \u003cspan\u003e\u003cspan class=\"acc-plus\" style=\"font-size: 22px; font-weight: 300; color: #c0392b;\"\u003e+\u003c\/span\u003e\u003cspan class=\"acc-minus\" style=\"font-size: 22px; font-weight: 300; color: #c0392b;\"\u003e−\u003c\/span\u003e\u003c\/span\u003e\n  \u003c\/summary\u003e\n  \u003cul style=\"padding: 4px 0 20px 18px; color: #444; line-height: 1.9;\"\u003e\n    \u003cli\u003eProvides 40W of constant emergency output power, automatically activating when AC power is interrupted and delivering 310–500VDC to maintain illumination through the connected LED driver.\u003c\/li\u003e\n    \u003cli\u003eDesigned exclusively for LED luminaires with an input voltage of 347–480VAC — this driver cannot be used with fixtures rated below 347VAC.\u003c\/li\u003e\n    \u003cli\u003ePowers 0-10V dimmable fixtures up to 300W; a 0-10V dimming driver is required for proper emergency operation on fixtures above the emergency driver's rated wattage.\u003c\/li\u003e\n    \u003cli\u003eAccepts a 277–480VAC input voltage range at 50\/60Hz, supporting 277V, 347V, and 480V commercial and industrial electrical systems.\u003c\/li\u003e\n    \u003cli\u003eIntegrated self-diagnostic circuitry automatically conducts a 30-second discharge test every 30 days and a full 90-minute discharge test every 365 days per NFPA 101 Life Safety Code, then restores to normal charging without manual intervention.\u003c\/li\u003e\n    \u003cli\u003eProvides a minimum of 90 minutes of constant emergency illumination in compliance with life-safety code requirements for commercial egress lighting.\u003c\/li\u003e\n    \u003cli\u003eThree-way battery protection covers over-temperature, over-charge, and over-discharge conditions to safeguard battery health and extend service life.\u003c\/li\u003e\n    \u003cli\u003eIP65 waterproof rating protects internal electronics against dust ingress and low-pressure water jets in damp or wet-adjacent locations.\u003c\/li\u003e\n    \u003cli\u003eBuilt-in 3kV surge protection guards the driver and connected fixture against transient voltage spikes in 480V industrial electrical environments.\u003c\/li\u003e\n    \u003cli\u003eLithium-ion battery pack with low 12W recharge power draws minimal standby current, with a full recharge time of 24 hours after complete discharge.\u003c\/li\u003e\n    \u003cli\u003eSlim profile body measures 12.33\" × 2.33\" × 1.66\" with flexible conduit wiring and ½\"-14 NPSM connector for clean in-fixture installation inside high bays, troffers, and panel housings.\u003c\/li\u003e\n    \u003cli\u003eIncluded test switch and charge indicator kit is available in metal one-piece or plastic integrated styles to suit different fixture and ceiling configurations.\u003c\/li\u003e\n    \u003cli\u003eRated for damp locations and plenum spaces with a maximum mounting height of 30.3 feet, suitable for industrial and high-ceiling commercial installations.\u003c\/li\u003e\n    \u003cli\u003eConstant power output design maintains consistent 40W delivery even as the lithium-ion battery voltage decreases during the discharge cycle.\u003c\/li\u003e\n    \u003cli\u003eUL Listed for the United States and Canada, tested to UL 924 and CSA C22.2 No. 141, and compliant with CEC Title 20 and NFPA 101 Life Safety Code requirements.\u003c\/li\u003e\n    \u003cli\u003eSuitable for both field retrofit of existing 480V fixtures and factory installation in new construction projects.\u003c\/li\u003e\n    \u003cli\u003eBacked by a 5-year warranty covering defects in materials and workmanship.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border-top: 1px solid #ddd; margin-top: 16px;\"\u003e\n  \u003csummary style=\"cursor: pointer; padding: 14px 0; font-size: 17px; font-weight: 600; color: #222; list-style: none; display: flex; justify-content: space-between; align-items: center;\"\u003e\n    Applications\n    \u003cspan\u003e\u003cspan class=\"acc-plus\" style=\"font-size: 22px; font-weight: 300; color: #c0392b;\"\u003e+\u003c\/span\u003e\u003cspan class=\"acc-minus\" style=\"font-size: 22px; font-weight: 300; color: #c0392b;\"\u003e−\u003c\/span\u003e\u003c\/span\u003e\n  \u003c\/summary\u003e\n  \u003cul style=\"padding: 4px 0 20px 18px; color: #444; line-height: 1.9;\"\u003e\n    \u003cli\u003e480V high bay fixtures in manufacturing plants, steel mills, and heavy industrial facilities with ceilings up to 30.3 feet\u003c\/li\u003e\n    \u003cli\u003e480V recessed troffers and LED panels in large commercial buildings, data centers, and utility control rooms\u003c\/li\u003e\n    \u003cli\u003eIndustrial warehouses, distribution hubs, and logistics centers operating on 480V three-phase electrical systems\u003c\/li\u003e\n    \u003cli\u003eAirport terminals, transit stations, and transportation hubs with 480V lighting infrastructure requiring emergency egress compliance\u003c\/li\u003e\n    \u003cli\u003eHospital mechanical floors, central plants, and healthcare facilities with 480V distribution systems\u003c\/li\u003e\n    \u003cli\u003eMulti-story commercial towers and campus buildings with 480V step-down transformer configurations\u003c\/li\u003e\n    \u003cli\u003eConvention centers, arenas, and large assembly venues with 480V lighting circuits subject to IBC and NFPA 101 requirements\u003c\/li\u003e\n    \u003cli\u003ePharmaceutical manufacturing, clean rooms, and laboratory facilities operating on 480V systems\u003c\/li\u003e\n    \u003cli\u003ePetrochemical plants, refineries, and energy sector facilities with 480V industrial lighting\u003c\/li\u003e\n    \u003cli\u003ePlenum-rated ceiling spaces in 480V commercial and industrial properties where above-ceiling driver placement is required\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/details\u003e\n\n\u003cdiv style=\"border-top: 1px solid #ddd; margin-top: 0;\"\u003e\u003c\/div\u003e","brand":"supertechlights","offers":[{"title":"Default Title","offer_id":49107681411380,"sku":"LSA-40AAAWW-HY","price":229.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/9041\/0548\/files\/supertechlights-40w-emergency-driver-03.jpg?v=1777318862","url":"https:\/\/supertechlights.com\/products\/40w-480v-emergency-led-driver-battery-backup-ul-924","provider":"SuperTech Lights","version":"1.0","type":"link"}